General
The
"VOC in Water" Air Stripper System based on the El Paso Method can aid in the
measurement of fugitive volatile materials, which can escape from cooling tower
water for example, and can be an indicator for process leaks and will allow plants
to conform to laws limiting such emissions.
Description
The RT-201 Air Stripper is based on a standardized
method and is the preferred system for reliably testing VOC (Volatile Organic
Compounds) in low PPM-concentrations with a FID-analyzer from cooling tower water.
It can also be used in a wide variety of other applications where VOC concentrations
in water need to be measured. When connected to a Total Hydrocarbon FID-analyzer
the RT-201 is a continuous on-line or transportable monitor, which provides the
measurement of low ppm concentrations of dissolved solvents in water. This could
be from cooling water, industrial waste- water, groundwater, process or rain water
run-off. Continuous monitoring is a reliable and effective method to improve the
process management for treating, discharging and detecting of dissolved VOCs in
water. Compared to the laboratory grab sample analysis method, the technique of
continuous on-line monitoring provides cost effective, remote and operator unattended
measurement of volatile hydrocarbons in water.
After
the RT-201 stripping unit is connected via a short sample line to FIA (Flame Ionization
Analyzer), it reliably measures strippable dissolved and dispersed volatile organic
compounds in water.
Typical Applications
- Cooling
Towers
- Condensate Water
- Holding
Ponds
- Heat Exchangers
- Waste
Water
- Process Stream Analysis
- Spray
Paint Booth
VOC in Cooling Tower
Water
Leaks of volatile hydrocarbons from heat exchangers may emit large amounts of
VOC which can cause emissions into the atmosphere or may create a hazard. Continuous
on-line monitoring gives an early warning of possible corrosion leaks. Savings
in lost product can be substantial.
VOC in Heat
Exchanger Water
The continuous monitoring of
volatile hydrocarbons in condensate or cooling water gives the possibly earliest
warnings for the development of leaks in a heat exchanger.
VOC
in Waste Water, Holding Ponds
Drainage run-offs,
equipment leaks or spills can be the cause for a build up of volatile hydrocarbons.
A VOC analyzer with the Model RT-201 continuously indicates the presence of VOC
in such waters. Features:
- Continuous monitoring
means uninterrupted real time measurement of VOCs in contaminated water.
- Direct
measurement does not require any sample pretreatment prior to measurement.
- Monitoring
process with a FID is more selective for the detection of VOC in the presence
of physical and chemical interference in contaminated water.
- Major
Applications are Continuous monitoring (or field monitoring) of VOCs in water
from cooling towers, cooling water outlets, condensers, heat exchangers, water
wells, spray paint systems, extraction water run off, rain water run off.