| | Source
Testing ("Stack Testing") | | | Industries
and Company References | - Chemical
- Petrochemical
- Plastics
- Refinery
- Steam Generation
- Printing
- Railcar/Truck Cleaning
- Marine
Terminals
- Bulk Terminals
- Water
Purification
- Coatings
- Coal-fired
Cogeneration
- Natural Gas Cogeneration
- Pulp
and Paper
- Medical Waste Incineration
- Hazardous
Waste Incineration
- Natural Gas Pipeline
- Midstream
and Upstream Gas Processing
| | | | | | | | | | | | | | | |
A
sampling of our clients includes the following: ATOFINA Chemicals, ATOFINA
Petrochemicals, Arkema, Crosstex Energy, Duke Energy, Dow Chemicals, Enterprise
Operating Products, Firestone, FMC, Georgia Gulf, Goodyear, Nisseki, Promix, Sunoco,
Sun Oil, TOTAL, TMPA, Ultrapak, and Vopak. | |
Test Methods | EnRUD's
expertise and extensively trained personnel routinely provide emissions testing
for our clients in accordance with EPA promulgated test methods and EPA conditional
test methods. EnRUD routinely samples for Oxygen, Carbon Dioxide, Sulfur Dioxide,
Carbon Monoxide, Total Hydrocarbons, VOCs, Acids, Chlorides, Aldehydes, Ammonia,
Ketones, Formaldehyde, Particulates, Particle Size Distribution, Dioxins/Furans,
Total Chromium, Hexavalent Chromium, Metals, Mercury, Volatiles, Semi-Volatiles,
Total Organics, Highly Reactive VOCs, and Opacity. EnRUD has extensively performed
the following type of source emissions testing: - Boiler
MACT Testing
- RICE MACT Testing
- Initial
Compliance Testing
- Recertification Testing
- Permit
Compliance Testing
- Flare Tests
- CEMs
and PEMs Certification
- Optimization and Tuning
for Boilers/Heaters/Turbines/Engines/Compressors
- Destruction
and Removal Efficiency (DRE) testing
- Comprehensive
Performance Testing (CPT) ("Trial Burns")
- Spiking
for CPT ("Trial Burns")
- ICE, RICE, and Compressor
Engine Compliance Testing
- Portable Testing of Engines/Compressors/Turbines
- HRVOC Vent Characterization studies
- HRVOC
Flare Line Characterization Studies and Testing
- HRVOC
Cooling Water Tower Testing
- "Mass Emission Rate"
testing ("Bagging")
- NOx, CO, and VOC Emissions
Testing
EnRUD is certified by Louisiana Environmental
Laboratory Accreditation Program (LELAP) in accordance with NELAP to perform the
following methods: - 40 CFR 60, Appendix A, Test
Method 1 through 29
- 40 CFR 60, Appendix B, Performance
Specifications 1 through 9
- 40 CFR 60, Appendix
F, CGAs and RATAs
- SW-846 Test Methods, 0010 through
0061
- 40 CFR 266, Appendix IX, Cal Error (CE) and
Relative Accuracy Test Audits (RATA)
| | Top |
CEMS | EnRUD
provides a turn-key operation for the building, installation, and certification
of a CEM system. | | Top |
CEM Repair | EnRUD
is the U.S. "Official" repair center for J.U.M Total Hydrocarbon Analzyers. EnRUD
is also an "Official" regional repair center for California Analytical analyzers
consisting of the following types: - Infrared,
- Non-Dispersive Infrared
- Chemiluminescent
- Paramagnetic.
EnRUD
has manufacturer trained personnel to complete and certify the work in compliance
with manufacturer's specifications. EnRUD only uses "manufacturer approved" components
for repair. With EnRUD's experience with building, installation and certification
of CEM systems, repairing of CEMS is a natural component of the "Complete" service
philosophy. | | Top |
CEMS Certification | EnRUD
provides CEMS and PEMS certifications for a variety of sources. Quarterly Cylinder
Gas Audits and/or Calibration Error tests are performed in conjunction with an
annual RATA. We carry the following analyzers in conjunction with a comprehensive
Data Acquisition system in our Mobile Testing Labs: - Oxygen
(O2) - EPA Method 3A, PS 3
- Carbon Dioxide (CO2)
- EPA Method 3A, PS 3
- Sulfur Dioxide (SO2) - EPA
Method 6C, PS 2
- Oxides of Nitrogen (NOx) - EPA
Method 7E, PS 2
- Carbon Monoxide (CO) - EPA Method
10, PS 4
- Total Hydrocarbons (THC) - EPA Method
25A, PS 8
- HRVOCs - PS 9
A
majority of the certifications are performed in compliance with EPA 40 CFR 60,
Appendix B, Performance Specifications (PS) 1 through 9 and 40 CFR 75 and 40 CFR
266, Appendix IX. | | Top |
RCRA & BIF Services | EnRUD's
Hazardous Waste Combustion RCRA and BIF services include: - Trial
Burn Plan Preparation
- Waste Feed Spiking
- Trial
Burn Testing
- DRE Burns
- Risk
Burns
- Comprehensive Performance Testing (CPT)
|
| Top |
Safety / Accreditation | EnRUD's
Source Testing Division has had a total of "zero" OSHA recordables. EnRUD
performs hazard identification and analysis for each and every test performed.
Each and every EnRUD field personnel goes through a rigorous safety program. The
combination of training and awareness has allowed us to maintain a current "zero"
recordable rate. EnRUD is currently accredited by
LELAP (Louisiana Environmental Laboratory Accreditation Program). LELAP has adopted
the NELAP (National Environmental Laboratory Program) standards. During the LELAP
accreditation process, LDEQ representatives visited our offices for a visual inspection,
reviewed EnRUD's QA/QC files, inspected EnRUD's equipment, reviewed EnRUD's Quality
Assurance Manual, reviewed EnRUD's SOP's and witnessed EnRUD's Source Testing
Division on an actual job which consisted of a two week trial burn (CPT test)
on a hazardous waste incinerator. | | Top |
|